1. VS1 12KV 11KV Vacuum Circuit Breaker

修改后8.jpg

ZN63(VS1)-12 Series Embedded Poles Type Indoor HV Vacuum Circuit Breaker, adopt solid insulation structure, use of advanced solid epoxy sealing technology, the first time, the vacuum interrupter. A leading electrical circuit. insulation and other support to become an integrated combination of solid seal pole. Successfully from a fundamental solution of the vacuum breaker gas environment, tolerance issues, make it more broad. Integrated solid-pole closure of the fluent use of a self-ventilation technology, cleverly solved the structure of solid insulation caused by heat dissipation.

2.Product parameter

ITEM

UNIT

DATA

Rated voltage

kV

12

Rated current

A

1250

Rated frequency

Hz

50

Rated insulation level

Lightning impulse
  withstand voltage

Phase to  phase,
  phase to earth

kV

75

Insulating distance
  of contact

85

1min power
  frequency
  withstand voltage

Phase to phase,
  phase to earth

42

Insulating distance
  of contact

49

4s rated short time withstand current

kA

31.5

Rated short circuit break current

/

31.5

Rated peak value withstand current

/

80

Rated short circuit making current

/

80

Rated operation sequence

O-0.3s-CO-180s-CO

Break times of rated short circuit current

Times

50

Mechanical life


20000

Break current of rated different phases earth fault

kA

27.4

Break current of rated single capacitor bank

A

400

Break current of rated back to back capacitor bank


400

Rated open operation voltage/current

V/A

DC(AC)220/1.1 DC(AC)110/2.2

Rated making operation voltage/current

DC(AC)220/1.1 DC(AC)110/2.2

Release work current of rated transient over current

A

5

Rated circuit of secondary circuit

V

DC(AC)220 DC(AC)110

Rated voltage of energy storage motor

DC(AC)220 DC(AC)110

Rated output power of energy storage motor

W

50

Energy storage time

s

≤10

1min power frequency withstand voltage
  of secondary circuit

V

2000

Insulating distance of contact

mm

11±1

Overtravel of contact

3+1 0

Center distance between  different poles

210±1

Allow abrasion thick of contact

3

Average opening speed

m/s

1.2±0.2

Average closing speed

0.7±0.2

Contact closing jump time

ms

≤2

Close/open synchronized of three phases

≤2

Main circuit resistance

μΩ

≤55

Opening time

ms

25~60

Closing time

35~75

Operation characteristic of operation mechanism

65%~120% rated voltage

Reliable open/close

≤30% rated voltage

Can not open

3. Application

Rated voltage(12kV) 
Rated short-time P.F. withstand voltage(1min.)(42kV) 
Rated lightning impulse withstand voltage(peak)(75kV) 
Rated power frequency(50/60Hz) 

Altitude: 1000m; 
Ambient temperature: -25 ~+40 ; 
Relative humidity: daily average 95 , monthly average 90 ; 
Earthquake intensity: 8 degree; 
Applicable occasions should free from inflammables, explosives, corrosives 

4.Technical detail


11kv VCB With Embedded Pole Of Draw-out Type ZN63-VS1.jpg

5. Factory show

公司风采(2).jpg

6. After serviceservice(1).jpg

7.Contact us

Phone: 0086 13319220197

Email: emma@zgxgdn.com

WhatsApp: 008613319220197

Skype: sunnysunny12271

Wechat: 13319220197

XIGAO Electricenergy Group Co.,LTD.

Add.: No. 6, Weibei Industrial Park, Xi'an City, Shaanxi Pro., CN. 710600 

Website:  www.zgxgdn.cn

Inquiry